Lorem ipsum dolor sit amet, consectetur adipiscing elit. Sed nibh augue, volutpat in finibus ac, bibendum non lectus. Aenean finibus nisi risus, lobortis lacinia ligula interdum id.

Specific Challenge

Scale Removal in a geothermal well

REGION - ITALY REGION - ITALY

Italy

REGION - ITALY

Challenge

  • Production in a geothermal well was slowly decreasing over the months
  • Attempts to bullhead acid with a small pump proved ineffective, as it could not reestablish optimum production rate
  • A run with Slick line confirmed an obstruction in the well, with a reduction of the 9 5/8" casing ID down to about 3“

Solution

  • Scale removal intervention, using the Pulsonix® TFA tool to enhance placement, remove obstructions, and propagate acid into the perforations
  • Fluid was continually pumped down CT/Tubing annulus to reduce surface temperature and protect the PCE - a sensor monitored the temperature
  • Plan was developed for an under-reamer, to enlarge the restriction after the acid run in if some scale couldn't be dissolved

Result

  • After a few cubic meters was pumped through the TFA tool, the well went to a total vacuum, which was what the customer wanted
  • The contingent run with PDM and under-reamer was not required - customer was satisfied with the unexpected results of the Pulsonix TFA treatment
  • Well injection rate more than doubled, indicating that the obstruction was removed and near wellbore connectivity was re-established